Home Source Measure Units SMU Source Measure Units SMU AIM-TTi SMU-LINK for SMU4000 Series Source Measure Unit (SMU)

AIM-TTi SMU-LINK for SMU4000 Series Source Measure Unit (SMU)

Availability: In stock


Product Code:
74660
Manufacturer: Aim-TTi
£106.00 £127.20

The SMU-LINK is an accessory that can be used to connect two SMUs together.

For use with the SMU4001 and SMU4201 single channel SMU from AIM-TTi.

More info and finance questions

The SMU-LINK is an accessory that can be used to connect two SMUs together to perform simultaneously via a handshake triggering system, effectively creating a fully functioning 2 channel SMU, useful for testing three leaded components such as small signal BJT’s, FET’s and more.

 

 

Aim-TTi SMU4201/4001

Display

4.3” Colour LCD w/touch-panel

Terminals

Front and Rear, Parallel

Size

250mm(W) x 97mm(H)

295mm(D)   2U ½ rack)

4.25kg

Interfaces

LAN

USB

GPIB (optional)

Flash Drive

8-port Digital

Channels

1

 

Operating Modes and Features

 

Modes

SV, SC

LC, LR and LP load modes with voltage dropout setting.

MV and MC measurement modes.

MR and MHR resistance measurement modes.

 

Shapes

Sweep (Lin/Log, Dual)

Pulse

Pulse Sweep

List

4-quadrant Voltage Source

 

Max Voltage

210V

Sensing

2- or 4-wire

Guarding

Yes

Resolution

0.1uV

Max Continuous Load

25W (with power flex limit)

3A @ <21V

0.5A @ 21-210V

Max Time Limited Load

As continuous

Ranges

5 Fixed or auto range

Accuracy

20mV:    0.06%rdg ± 50µV

200mV:  0.015%rdg ± 50µV

2V:         0.015%rdg ± 50µV

20V:       0.02%rdg ± 5mV

200V:     0.02%rdg ± 5mV

AC Noise (rms, typ)

<2mV @ <21V / 20MHz

<3.5mV @ 21-210V / 20MHz

 

Reach to 0.1% (typ)

300us independent of voltage

No Load

 

 

 

Slew Rate

Adjustable up to 1.2V/us

Overshoot (typ)

0.5%+1mV

Capacitive Loading

Normal : stable to 0.2uF

HiC : stable to >200uF

Protection

OVP

OCP

OTP

OPP

4-quadrant Current Source/Load

 

Max Current

3A

Sensing

2- or 4-wire

Guarding

Yes

Resolution

100fA

Max Continuous Load

25W (with power flex)

3A @ <21V

0.5A @ 21-210V

Max Time Limited Load

As continuous

Ranges

9, Fixed or auto-range

Accuracy

200nA:  0.04%rdg ± 300pA

2uA:      0.03%rdg ± 300pA

20uA:    0.02%rdg ± 2nA

200uA:  0.02%rdg ± 2nA

2mA:     0.02%rdg ± 200nA

20mA:   0.02%rdg ± 2uA

200mA: 0.02%rdg ± 20µA

1A:        0.07%rdg ± 100µA

3A:        0.2%rdg ± 300µA

 

Settling (typ)

2.5ms < 210uA

Shorted Load

600us < 2.1mA

 

200us < 3.15A

 

 

Slew Rate

Adjustable up to 36mA/us

Measurements

 

Digitize Results

5ksps

Measurement Results

200us-20s or 0.01-100PLC

1ppm resolution

Voltage and current with no speed penalty

Measurement Accuracy

Same as sourcing accuracy

Math Capabilities

Can be configured to perform (x-c), (mx+c), ((x-c) /c) or (x/c) on either measurement result.

Limit and Binning Capabilities

Tolerance checking on any measurement result.

Remote binning can be performed using sequence mode and DIO.

 

Write Your Own Review
You're reviewing:AIM-TTi SMU-LINK for SMU4000 Series Source Measure Unit (SMU)
Your Rating
PhotoProduct SKU
AIM-TTi SMU4001 Source Measure Unit (SMU) ±21VAIM-TTi SMU4001 Source Measure Unit (SMU) ±21V- >
AIM-TTi SMU4201 Source Measure Unit (SMU) ±210VAIM-TTi SMU4201 Source Measure Unit (SMU) ±210V- >
SRS CS580 Voltage Controlled Current Source, ±50 V, 100fA to 100mASRS CS580 Voltage Controlled Current Source, ±50 V, 100fA to 100mA- >
SRS DC215 — Precision DC Voltage/Current SourceSRS DC215 — Precision DC Voltage/Current Source- >
SRS DC205 Precision DC Voltage SourceSRS DC205 Precision DC Voltage Source- >