Home Lock-In Amplifiers SRS SR844 DSP RF Lock-in Amplifier, 200MHz

SRS SR844 DSP RF Lock-in Amplifier, 200MHz

Product Code:
14979
Manufacturer: Stanford Research Systems
  • 25 kHz to 200 MHz frequency range
  • >80 dB dynamic reserve
  • Time constants from 100 µs to 30 ks (6, 12, 18 or 24 dB/oct rolloff)
  • "No Time Constant" mode (10 to 20 µs update rate)
  • Auto-gain, -phase, -reserve and -offset
  • Internal or external reference
  • Two 16-bit DACs and ADCs
  • GPIB and RS-232 interfaces

More info and finance questions

Request a Quote

Lambda Exclusive Promotion:
Additional 12 months warranty for free (2 years total) via our UK Service Centre.

The Stanford Research Systems SR844 is the widest bandwidth lock-in amplifier available. It provides uncompromised performance with a frequency range of 25 kHz to 200 MHz and up to 80 dB of drift-free dynamic reserve. The SRS SR844 includes the many features, ease of operation, and programmability that you've come to expect from SRS DSP lock-in amplifiers.

The SR844 uses the same advanced DSP technology found in the SR850, SR830 and SR810 lock-in amplifiers. DSP offers many advantages over analog instruments—high dynamic reserve, low zero-drift, accurate RF phase shifts and orthogonality, and digital output filtering.

Auto-functions allow parameters that are frequently adjusted to be set automatically. Sensitivity, dynamic reserve, phase and offset are each quickly optimized with a simple key stroke.

The offset and expand features are useful for evaluating small fluctuations in your signal. The input is nulled with the auto-offset function, and output expand increases the resolution by up to 100×.

Ratio mode is used to normalise the signal to an externally applied analog voltage. It is useful to eliminate the effect of source intensity fluctuations.
Transfer function measurements can be easily made from the front panel by a programmable scan of up to 11 frequencies. Setups and offsets are recalled at each frequency in the scan.

Inputs & Outputs

Analog Inputs and Outputs
The two displays each have a user-defined output for measuring X, Y, R, R(dBm), Θ, and X-noise or Y-noise. Two user-programmable DACs provide -10.5 V to +10.5 V outputs with 1 mV resolution. These outputs may be set from the front panel or via the computer interfaces.

In addition, there are two general purpose analog inputs. These are 16-bit ADCs which can be displayed on the front panel, read over the interface, or used to ratio the input signal.

Signal Input
The SR844 has both 50 Ω and 1 M Ω inputs. The 1 MΩ input is used with high source impedances at low frequencies, or with a standard 10× scope probe. The 50 Ω input provides the best RF signal matching. Full-scale sensitivities range from 1 Vrms (+13 dBm) down to 100 nVrms (-127 dBm). Up to 60 dB of RF attenuation or 20 dB of RF gain can be selected in 20 dB increments. Gain allocation can be optimized to provide up to 80 dB of dynamic reserve.

Reference
The SR844 offers both external and internal reference operation. In both cases, the entire 25 kHz to 200 MHz frequency range is covered without any manual range selection. The external reference input has an auto-threshold feature which locks to sine, square or pulsed signals. The internal reference is digitally synthesized and is adjustable with 3-digit frequency resolution.

Harmonic detection of the 2F component is available for both internal and external reference modes.

A reference output (1.0 Vpp square wave into 50 Ω) which is phase synchronous with the lock-in reference is available in both external and internal mode.

Output Filters
Time constants from 100 µs to 30 ks can be selected with a choice of 6, 12, 18 or 24 dB/oct rolloff. For high-bandwidth, real-time outputs, the filtering can be by-passed entirely. In this "No Filter" mode, the effective time constant is about 30 µs, with the analog outputs updating every 10 to 20 µs.

Ease of Operation
The SR844 is easy to use. All instrument functions are set from the front-panel keypad, and the knob is used to quickly adjust parameters. Up to nine different instrument configurations can be stored in non-volatile memory for fast, reliable instrument setup. Standard RS-232 and GPIB (IEEE-488.2) interfaces provide connections to your data acquisition systems.

Internal Memory
The SR844 has two 16,000 point memory buffers for recording the time history of each measurement display at rates up to 512 samples/s. Data may be transferred from the buffers using either interface. A trigger input is also provided to synchronize data recording with external events.

Additional Information

Specification
Max. Frequency200MHz
TypeDSP
Signal Channel 
Voltage inputs Single-ended BNC
Input impedance 50 Ω or 1 MΩ + 30 pF
Damage threshold ±5 V (DC + AC)
Bandwidth 25 kHz to 200 MHz
Sensitivity:
  < 1 MHz
  < 50 MHz
  < 200 MHz

100 nVrms to 1 Vrms full scale
1µVrms to 1 Vrms full scale
10 µVrms to 1 Vrms full scale
Gain accuracy:
  < 50 MHz
  < 200 MHz

± 0.25 dB
± 0.50 dB
Gain stability 0.2 %/°C
Coherent pickup Low-noise reserve, sens. <30mV
  f < 10 MHz <100 nV (typ.)
  f < 50 MHz <2.5µV (typ.)
  f < 200 MHz <25µV (typ.)
Input noise (50 Ω) 2 nV/√ Hz (typ.), 8 nV/√Hz (max.)
Input noise (1 MΩ), 5 nV/√Hz (typ.), 8 nV/√Hz (max.)
Dynamic reserve up to 80 dB
   
Reference Channel 
External reference input 25 kHz to 200 MHz
Impedance 50 Ω or 10 kΩ + 40 pF
Level 0.7 Vpp pulse or 0 dBm sine
Pulse width >2 ns at any frequency
Threshold setting Automatic, midpoint of waveform

Acquisition time

 

10s auto ranging any frequency

1s within same octave

Internal reference 25 kHz to 200 MHz)
Frequency resolution 3 digits
Frequency accuracy ±0.1 in the 3rd digit
Harmonic detection 2F (50 kHz to 200 MHz)
Reference outputs Phase locked to Int. or Ext. reference
Front panel ref output 25 kHz to 200 MHz square wave, 1.0 Vpp nominal into 50 Ω
Rear panel TTL output 25 kHz to 1.5 MHz, 0 to +5 V nominal, =3 V into 50 Ω
Phase resolution 0.02°

Absolute phase error:

50 MHz

100 MHz

200 MHz

 

2.5o

5.0o

10.0o

Rel. phase error, orthog. <2.5°
Phase noise (external) 0.005° rms at 100 MHz, 100 ms time constant

Phase drift:

 

 

<0.1o/oC

<0.25o/oC

<0.5o/oC

   
Demodulator 
Zero stability Digital displays have no zero-drift. Analog outputs have
Time constants 100 µs to 30 ks with 6, 12, 18 or 24 dB/octave rolloff
”No Filter” mode 10 to 20 µs update rate (X and Y)
Harmonic rejection: Harmonic rejection:
Odd harmonics -9.5 dBc @3 × ref, -14 dBc @5 × ref, etc. (20log 1/n where n = 3, 5, 7, 9...)
Even harmonics <-40dBc
Sub-harmonics <-40dBc

Spurious responses

 

-10 dBc @ ref ± 2 × IF

-23 dBc @ref ± 4 x IF

   
Displays 
Channel 1:  
Type 4½-digit LED with 40-segment bar graph
Quantities X, R[V or dBm], X-noise, Aux In 1
Channel 2:  
Type 4½-digit LED with 40-segment bar graph
Quantities Y, Θ, Y-noise[V or dBm], Aux In 2
Expand ×10 or ×100 for Ch1 and Ch2

Ratio

 

X and Y ratioed with respect to Aux In 1 or Aux In 2 before filtering and computation of R.

The ratio input is normalized to 1 V and has a dynamic range greater than 100.

Reference:  
Type 4½-digit LED
Quantities Reference Frequency, Phase, Offsets, Aux Out, IF Frequency, Elapsed Time
   
Channel 1 and Channel 2 Outputs 
Voltage range ±10 V full scale proportional to X, Y or CH1, CH2 displayed quantity
Update Rate:  
X, Y 48 to 96 kHz
R, Θ, Aux inputs 12 to 24 kHz
X-noise, Y-noise 512 Hz
   
Auxiliary Inputs and Outputs 
Inputs 2
Type Differential, 1 MΩ
Range ±10 V
Resolution 0.33 mV
Bandwidth 3 kHz
Outputs 2
Range ±10 V
Resolution 1 mV
Data Buffers Two 16,000 point buffers. Data is recorded at rates up to 512 Hz and is read using the computer interfaces.
   
General
Interfaces IEEE-488.2 and RS-232 interfaces are standard. All instrument functions can be controlled and read through the interfaces.
Power 70 W, 100/120/220/240 VAC, 50/60 Hz
Dimensions 17" × 5.25" × 19.5" (WHL)
Weight 23 lbs.
Warranty One year parts and labor on defects in materials and workmanship
Additional 12 months warranty for free (2 years total) via our UK Service Centre.
Write Your Own Review
You're reviewing:SRS SR844 DSP RF Lock-in Amplifier, 200MHz
Your Rating
PhotoProduct Max. Frequency Type SKU
SRS SR860 DSP Lock-in Amplifier, 500 kHz SRS SR860 DSP Lock-in Amplifier, 500 kHz 500kHzDSP- >
SRS SR865A DSP Lock-In Amplifier, 4MHzSRS SR865A DSP Lock-In Amplifier, 4MHz4MHzDSP- >
DISCONTINUED SRS SR830 DSP Lock-in Amplifier, 102kHzDISCONTINUED SRS SR830 DSP Lock-in Amplifier, 102kHz100kHzDSP- >
SRS SR850 DSP Lock-in Amplifier, 102kHzSRS SR850 DSP Lock-in Amplifier, 102kHz100kHzDSP- >
SRS SR2124 - 200 kHz Analogue/Analog Lock-in AmplifierSRS SR2124 - 200 kHz Analogue/Analog Lock-in Amplifier200kHzAnalogue- >
SRS SX199 Optical Interface ControllerSRS SX199 Optical Interface Controller--- >
DISCONTINUED SRS SR530 Analogue Lock-in Amplifier, 100kHzDISCONTINUED SRS SR530 Analogue Lock-in Amplifier, 100kHz100kHzAnalogue- >
SRS SR510 Analogue Lock-in Amplifier, 100kHzSRS SR510 Analogue Lock-in Amplifier, 100kHz100kHzAnalogue- >