Home Rigol Advanced Measurement Kit DSA800-AMK

Rigol Advanced Measurement Kit DSA800-AMK

Availability: In stock


Product Code:
38464
Manufacturer:
£411.00 £493.20
Spectrum analyser measurement package option

More info and finance questions

The Rigol DSA800-AMK Advanced Measurement Kit Option provides measurement functions. These include:

  • T-Power: The system enters zero span mode and calculates the power within the time domain. The types of powers available include Peak, Average and RMS.
  • Adjacent Channel Power (ACP): This function is able to  measure the powers of the main channel and adjacent channels. Additionally the power difference between the main channel and each of the adjacent channels can be calculated. When this function is enabled, the span and resolution bandwidth of the analyzer are adjusted to smaller values automatically.
  • Channel Power (Chan Pwr): Measure the power and power spectral density within the specified channel bandwidth. When this function is enabled, the span and resolution bandwidth are automatically adjusted to smaller values.
  • Occupied Bandwidth (OBW): Integrates the power within the whole span and calculates the bandwidth occupied by this power according to the specified power ratio. The OBW function is able to indicate the difference between the centre frequency of the channel under measurement and the centre frequency of the analyser.
  • Emission Bandwidth (EBW): Measures the bandwidth between two points on the signal that are X dB below the highest point within the span.
  • C/N Ratio: Measures the power of the carrier and noise with the specified bandwidths as well as their power ratio.
  • Harmonic Distortion (Harmo Dist): Measures the power of each order of harmonic and THD (total harmonic distortion) of the carrier. The highest order of harmonic available is 10 and the fundamental wave amplitude must be greater than -50 dBm. If this is not seen the measurement will be invalid.
  • Third-Order Inter-modulation TOI: Measures the parameters of the TOI production of two signals with the same amplitude and similar frequency. Those parameters include the frequencies and amplitudes of the Base Lower, Base Upper, 3rd-Order Lower and 3rd-Order Upper signal. Additionally, the Intercepts of both the Base Lower and Base Upper can be monitored.

Within the advanced measurement functions, the measurement mode can be single or continuous. It is possible to control the measurement including Restart, Pause and Resume.

Please add Serial Number (SN) information into the Notes Section when placing an order for Software Updates.

We have no downloads available for this product.

Write Your Own Review
You're reviewing:Rigol Advanced Measurement Kit DSA800-AMK
Your Rating
PhotoProduct