Mode Conditioners enable Luna’s Optical Backscatter Reflectometer (OBR) products to better locate and analyse faults in multimode fibre. Luna’s OBR’s have a single-mode FC/APC front panel connection. These Mode Conditioners redistribute a portion of light from the fundamental propagation mode in multimode fibre into several higher order modes making the OBR system more sensitive to faults that affect these modes such as tight bends, bad splices and cladding defects.
- Redistribute light from the fundamental mode to higher order modes
- 50/125 μm (OM1) and 62.5/125 μm (OM2, OM3, OM4) standard fibres
- Available with either FC/PC, SC/PC, LC/PC and ST/PC connector
- Rugged design for field use with Luna’s portable high-resolution OBR
- Fault location in multimode fibre networks, saving hours of troubleshooting time
PARAMETER |
SPECIFICATIONS |
UNITS |
|
Core/clad |
50/125 |
62.5/125 |
μm |
Wavelength range |
1525 - 1610 |
1525 - 1610 |
nm |
Insertion loss (typical) |
< 5.0 |
< 6.0 |
dB |
Return loss |
< 55 |
< 55 |
dB |
Length |
1.0 ± 0.05 |
1.0 ± 0.05 |
m |
Weight |
< 100 |
< 100 |
g |
Models |
50/125 |
62.5/125 |
MC01000 |
50μm, FC/PC |
x |
MC01001 |
50μm, SC/PC |
x |
MC01002 |
50μm, LC/PC |
x |
MC01003 |
50μm, ST/PC |
x |
MC01004 |
x |
62.5μm, FC/PC |
MC01005 |
x |
62.5μm, SC/PC |
MC01006 |
x |
62.5μm, LC/PC |
MC01007 |
x |
62.5μm, ST/PC |