Jasco IRT-7100 FTIR Microscope
Fully automated FTIR microscope with single-point mid-band MCT detector, field-upgradable to an IR imaging system by adding an optional 16-channel linear array detector. The standard automatic sample stage and “IQ Mapping” function provide wide area mapping and multi-ATR mapping.
The IRT-7100 fully automated FTIR microscope includes a single-point mid-band MCT detector, with the option to install an additional internal detector. It can be easily field-upgradable to a linear array imaging system by adding an optional 16-channel MCT detector. The automatic sample stage and IQ Mapping provide wide area mapping and multi-ATR mapping.
- Fully automated sample stage with autofocus
- IQ Mapping
- Multiple objectives with a 4-position motorized objective carousel
- Dual detector ready (optional second detector or user-swappable detectors)
- Field upgrade to high-speed IR Imaging System using a 16-element linear array detector
ClearView™ ATR
The ClearView™ ATR objectives allow both viewing of the sample through the crystal and ATR spectral measurement by simply moving the prism position (up and down). ATOS allows the aperture to select a specific area of the sample while viewing the entire area in contact with the crystal. In the application below, a mixed fiber was measured around the striated area in contact with the crystal. The spectra taken at two different measurement points show that the sample is composed of a mixture of nylon (light area) and acrylic (darker area).
Purge and Full-Vacuum System
Absorption peaks due to atmospheric water vapour and CO2 can make it difficult to obtain high-quality sample spectra. The standard microscope and FTIR optical system include multi-zone purge to reduce the effects of atmospheric gases, but the most effective solution is the measurement of samples in a vacuum. The IRT-5000 series can be configured as a full vacuum FTIR microscope system.
User-Friendly Micro Analysis Measurement Program
Spectra Manager™ Suite provides many automated functions with a simplified operation. Measurement conditions, microscope sample monitoring/control operations and measurement results can be reviewed in a single screen. The dedicated microscope interface provides various types of measurements such as single and multiple points, mapping, and linear array measurements using a single mouse click for mode selection. Real-time monitoring of the spectrum and a calculated functional group image can be specified during mapping measurement.
IRT-5200 | IRT-7100 | IRT-7200 |
Single-element mid-band MCT (7,800 600 cm 1) | Single-element mid-band MCT (7,800 600 cm 1) | Single-element mid-band MCT (7,800 600 cm-1) |
1x 16 element Linear Array MCT (7,000 650 cm 1) | ||
Dual Detector Capability | Dual Detector Capability | Standard Dual Detectors |
Optional Detectors | ||
N-MCT M-MCT W-MCT. InSb InGaAs Linear Array MCT | N-MCT, W-MCT, InSb, InGaAs Linear Array MCT | N-MCT, W-MCT, InSb, InGaAs |
Measurement Methods | ||
Transmittance, Reflectance, ATR, RAS | Transmittance, Reflectance, ATR, RAS | Transmittance, Reflectance, ATR, RAS |
Mapping | ||
Single Point, Multi-point, Line, Grid, and Micro-ATR Mapping Measurement | Single Point, Multi-point Line, Grid, and Micro-ATR Mapping Measurement | Single Point Multi-point Line Grid, and Micro-ATR Mapping Measurement |
IQ Mapping | IQ Mapping | IQ Mapping |
(Depends on objective up to 1.6 x 1.6mm example 400 x 400 um with x16 Cassegrain) | (Depends on objective up to 1.6 x 1.6mm example 400 x 400 um with x16 Cassegrain) | (Depends on objective up to 1.6 x 1.6mm example 400 x 400 um with x16 Cassegrain) |
Wide Area Mapping (10x7.5cm) | Wide Area Mapping (10x7.5cm) | |
High Speed Mapping (10 data/sec) | High Speed Mapping (10 data/sec) | |
High Speed High Resolution Mapping (160 data/sec) | ||
Standard Components | ||
Manual XYZ Stage | Auto XYZ Stage | Auto XYZ Stage |
Movable distance X: 70, Y: 50, Z:20 mm | Movable distance x 100, Y 75, 2:25 mm 1 um step | Movable distance X: 100, Y: 75, Z:25 mm, 1 um step |
Upgradable to Auto XYZ Stage | ||
4-Objective Carousel | 4-Objective Carousel | 4-Objective Carousel |
Control Panel | Control Panel | Control Panel |
CMOS Camera | CMOS Camera | CMOS Camera |
Purge | ||
Microscope purge (standard). | Microscope purge (standard). | Microscope purge (standard). |
Sample stage purge-case (option). | Sample stage purge-case (option). | Sample stage purge-case (option). |
Vacuum (option). | Vacuum (option). | Vacuum (option). |
Optional Components | ||
Joystick for Auto XYZ Stage | Joystick for Auto XYZ Stage | Joystick for Auto XYZ Stage |
Pressure Stage | Pressure Stage | Pressure Stage |
Required for ATR Objectives | Required for ATR Objectives | Required for ATR Objectives |
Standard Objectives | ||
16x Cassegrain (Aluminum) | 16x Cassegrain (Aluminum) | 16x Cassegrain (Aluminum) |
Optional Objectives | ||
Cassegrain Objectives | Cassegrain Objectives | Cassegrain Objectives |
Gold (Au): 10x, 16x, 32x | Gold (Au): 10x, 16x, 32x | Gold (Au): 10x, 16x, 32x |
Aluminum (Al): 10x, 32x | Aluminum (Al): 10x, 32x | Aluminum (Al): 10x, 32x |
Refractive Objectives | Refractive Objectives | Refractive Objectives |
4x, 10x, 20x | 4x, 10x, 20x | 4x, 10x, 20x |
ClearView ATR Objectives | ||
ATR-5000-SS | ATR-5000-SS | ATR-5000-SS |
(Zinc Sulfide) | (Zinc Sulfide) | (Zinc Sulfide) |
ATR-5000-SD | ATR-5000-SD | ATR-5000-SD |
(Diamond) | (Diamond) | (Diamond) |
ATR-5000-SG | ATR-5000-SG | ATR-5000-SG |
(Germanium) | (Germanium) | (Germanium) |
Wide-Area ATR Objectives | ||
ATR-5000-MG | ATR-5000-MG | ATR-5000-MG |
(Germanium) | (Germanium) | (Germanium) |
ATR-5000-WG | ATR-5000-WG | ATR-5000-WG |
(Germanium) | (Germanium) | (Germanium) |
Projection Type ATR Objectives | ||
ATR-5000-G45 | ATR-5000-G45 | ATR-5000-G45 |
(Germanium) | (Germanium) | (Germanium) |
Conventional Type ATR Objectives | ||
ATR-5000-Z | ATR-5000-Z | ATR-5000-Z |
(Zinc Selenide) | (Zinc Selenide) | (Zinc Selenide) |
ATR-5000-D | ATR-5000-D | ATR-5000-D |
(Diamond) | (Diamond) | (Diamond) |
ATR-5000-G | ATR-5000-G | ATR-5000-G |
(Germanium) | (Germanium) | (Germanium) |
Dimensions | ||
587 (H) × 302 (W) × 695 (D) mm 54 kg | 613 (H) × 302 (W) × 695 (D) mm 56 kg | 613 (H) × 302 (W) × 695 (D) mm 56 kg |