CI Systems SR-800N Superior Accuracy Blackbody
- Superior accuracy
- mK resolution
- High uniformity
- Wide range of temperatures
- Capable of operating at a wide range of ambient temperatures
- Calibrated radiation heads independent of the controller
- Quick and convenient annual calibration by removable sensor replacement
CI Systems’ advanced architecture ControlMaster SR-800N sets a new standard for accuracy and uniformity in extended area blackbodies. Temperature measurement and calibration are both performed in the radiation head itself and then transferred digitally to the controller. The result is accurate, stable, reliable and NIST-traceable. Temperature control is achieved using removable sensors that can easily be replaced by the user in just minutes.
Factory-supplied replacement sensors provide an effective and efficient method for recalibrating the system, for an additional 12 months of service. Alternatively, customers may recalibrate the blackbody with our optional CK-800R calibration kit.
- Configurable resolution and stability window
- Ethernet and RS232 communication ports, USB
- Communication by Serial Adaptor
- High resolution color display
- Built-in tests to shorten maintenance time
-
2" to 40’’ standard emitters. Other dimensions are available upon request
- Low acoustical noise
- Large color LCD display
- Touch screen user interface
- Nitrogen inlet for inert atmosphere on all LT models
- Compact and portable controller
- 19” rack mount kit included
- LINUX operating system
- Ability to control up to four motorized devices (optional)
- Dual head (optional)
NIST-traceable calibration
Certified to MIL-T-28800D, CE, and FCC
SR-800 Options
SR-800 Model |
2A / 2D |
4A / 4D |
7A / 7D |
8A / 8D |
10A / 10D |
12A / 12D |
14A / 14D |
16A / 16D |
20A / 20D |
|
Extended Temperature (ET)
|
Absolute temp. range,°C |
0 to 175 |
0 to 125 |
5 to 125 |
||||||
Differential temp. range,°C |
-25 to +150 |
-25 to +150 |
-25 to +150 |
-25 to +100 |
-20 to +100 |
|||||
Low Temperature (LT)
|
Absolute temp. range,°C |
--- |
-40 to +150 |
-40 to +150 |
-40 to +150 |
---
|
--- |
---
|
||
Differential temp. range,°C |
---
|
-65 to +125 |
-65 to +125 |
-65 to +125 |
--- |
--- |
--- |
|||
Wide Temperature Range (WTR ) |
Absolute temp. range,°C |
--- |
-20 to +150 |
-20 to +150 |
--- |
--- |
--- |
--- |
--- |
--- |
Differential temp. range,°C |
--- |
-45 to +125 |
-45 to +125 |
--- |
--- |
--- |
--- |
--- |
--- |
|
High Emissivity (HE)
|
0.99±0.01
|
---
|
||||||||
Environmental Chamber
|
|
|
||||||||
CH-STD Chamber temp. °C |
-30 to +70 |
|||||||||
Abs. temp. range °C |
-40 to +80 |
|||||||||
Diff. temp. range °C |
-10 to +40 |
|||||||||
CH-ET Chamber temp. ° C |
40 to +80 |
|||||||||
Abs. temp. range °C |
-40 to +150 |
|||||||||
Diff. temp. range °C |
-20 to +125 |
-20 to +100 |
-15 to +100 |
|||||||
CH-LT Chamber temp. °C |
--- |
-40 to +80 |
--- |
--- |
--- |
|||||
Abs. temp. range °C |
--- |
-40 to +150 |
--- |
--- |
--- |
|||||
Diff. temp. range °C |
--- |
-65 to +125 |
--- |
--- |
--- |
|||||
Differential Accuracy °C |
0.020 @ -20 < Tamb. < 80 , 0.040 @ Tamb. < -20 |
|||||||||
Stability,°C |
0.005 @ ∆T < 10 , 0.010 @ ∆T > 10 |
|||||||||
Dual blackbody head option |
Absolute Temperature Range,°C |
0 to +100 |
0 to +100 |
0 to 90 |
--- |
|
--- |
--- |
--- |
--- |
Differential Temperature Range,°C |
-25 to +75 |
-25 to +75 |
-25 to +55 |
--- |
|
--- |
--- |
--- |
--- |
|
GPIB Optional |
|
|
|
|
|
|
|
|
|
SR-800 Model |
2A / 2D |
4A / 4D |
7A / 7D |
8A / 8D |
10A / 10D |
12A / 12D |
14A / 14D |
16A / 16D |
20A / 20D |
40A / 40D |
Aperture |
2” diameter |
4”x4” |
7”x7” |
8”x8” |
10”x10” |
12”x12” |
14”x14” |
16”x16” |
20”x20” |
40”x40” |
Absolute temp. range, °C |
0ºC to 125ºC |
0ºC to 125ºC |
0ºC to 90ºC |
0ºC to 100ºC |
0ºC to 100ºC |
10ºC to 80ºC |
10ºC to 80ºC |
10ºC to 80ºC
|
10ºC to 80ºC |
10ºC to 80ºC |
Differential temp. range,°C |
-25ºCto 100ºC |
-25ºC to 100ºC |
-25ºC to 65ºC |
-25ºC to 75ºC |
-25ºC to 75ºC |
-15ºC to 55ºC |
-15ºC to 55ºC |
-15ºC to 55ºC |
-15ºC to 55ºC |
-15ºC to 55ºC |
Uniformity, °C |
± 0.005ºC |
± 0.010 |
± 0.010 |
± 0.010 |
± 0.010 |
± 0.010 |
± 0.015ºC |
± 0.015ºC |
± 0.015ºC |
± 0.030 |
Set point & readout resolution, °C |
0.001 |
|||||||||
Temperature accuracy : Absolute, °C |
0.015 @ Δ T< 0 , 0.007 @ 0 < T < 50 , 0.015 @ Δ T > 50 |
|||||||||
Temperature accuracy : Differential, °C |
0.008 @ Δ T ±25 , 0.015 @ Δ T ±25 |
|||||||||
Stability °C |
± 0.003 @ ΔT< ±10 , ± 0.008 @ ΔT> ±10 |
|||||||||
Emissivity |
0.98± 0.01 |
|||||||||
Settling time, sec |
30 |
|||||||||
Power consumption |
200 W |
200 W |
250 W |
1000 W |
1000 W |
1200 W |
2400 W |
3200 W |
4500 W |
6000 W |
Head size (HxW), mm
|
Ø 65 |
161x201 |
224x265 |
350x305 |
280x335 |
357x415 |
410x480 |
500x550 |
570x640 |
1280x760 |
Head size (Depth), mm |
95 |
190 |
225 |
170 |
170 |
230 |
170 |
170 |
170 |
1600 |
Head weight, kg
|
1 kg |
5 kg |
10 kg |
20 kg |
15 kg |
25 kg |
36 kg |
42 kg |
65 kg |
450 kg |
Controller dimensions, mm |
342x310x133 (3U)
|
450x600x175 (4U)
|
||||||||
Controller weight, kg |
10 |
10 |
10 |
10 |
10 |
10 |
20 |
20 |
25 |
60 |