Apex OCSA-APX High Resolution Complex Optical Spectrum Analyser
Ideal solution for Telecommunication applications, the APEX Optical Spectrum Analyzer (OSA) Series is equipped with the high resolution of 20 MHz/0.16 pm, as well as other resolution bandwidth from 140 MHz to 250 GHz. Additionally, the complex OSAs offer additional time domain measurement capability, including intensity, phase and chirp measurements
Available options:
- The optical output of the built-in Tunable Laser Source (TLS), which could also be used for component analysis (tracking funciton);
- 2 additional PM inputs
- Polarisation analysis is possible through a polarimeter (SOP and DOP measurement). This option can displacy three polarisation modes: Jones graph, Poincaré sphere and Stokes parameter oscilloscope.
Features:
- Resolution from 250 GHz to 140 MHz, up to 20 MHz/0.16 pm High Resolution
- 3 models: C Band / L Band / C&L Band
- Dynamic range 78 dB
- Rectangular-shape resolution filters
- 2 channels, one per polarisation axis
- Built-in tunable laser source
- Component transmission/reflection analysis
- 5 MHz resolution optional
Applications:
- Advanced modulation formats analysis
- Comb generator measurement
- Laser characterisation
- OSNR measurement
- OFDM analysis
- Optical sensor/component characterisation
Data handling:
- USB connectors
- Ethernet
- GPIB connector
- Sensitive screen
ComparisonTable:
OSA-AP1 | OSA-AP5 & OCSA-AP5 |
OSA-AP6 & OCSA-AP6 |
||
Wavelength ranges (depending on built-in Tunable Laser(s) possibility(es)) | ||||
Around 1064 nm | X | |||
O Band | X | |||
E Band | X | |||
S Band | X | |||
C Band | X | |||
L Band | X | |||
C + L Bands | X | |||
Resolution Bandwidth | ||||
Resolution Bandwidth | 5MHz | Optional | X | X |
20MHz | X | X | X | |
100MHz | Optional | X | X | |
140MHz | X | X | X | |
Virtual bandwidth resolutions | X | X | X | |
Built-in Tunable Laser Source Type |
||||
DFB Laser | X | |||
External cavity laser (Littman-Metcalf principle) | X | X | ||
Sweep Speed (Max.) |
||||
1.2nm/s | X | |||
35nm/s | X | X | ||
Possibility to Integrate Several Tunable Lasers | ||||
Built-in Tunable Laser(s) room | 2 Lasers room | 1 Laser room | 4 Lasers room | |
Complex Measurement |
||||
Complex analysis (intensity, phase, chirp vs. time); constellation, eye diagram | X OCSA-AP5 | X OCSA-AP6 | ||
Possibility to upgrade an OSA-APX into an OCSA-APX | ||||
Upgradable equipment | X | X | ||
Possibility to upgrade with additional built-in Tunable Laser(s) | ||||
Upgradable equipment | X | X |
OSA-AP1 | OSA-AP5 | OSA-AP6 | ||||||
Wavelength measurement range a |
Option OSA-AP1-C: From 1526 to 1567 nm |
Option OSA-AP1-L: From 1567 to 1608 nm |
T band TILS from 1030 to 1070 nm |
O band TLS from 1260 to 1360 nm |
E band TLS from 1335 to 1435 nm |
S band TLS from 1435 to 1520 nm |
C+L band TLS from 1525 to 1607 nm |
Extended C+L band TLS from 1520 to 1630 nm |
Wavelength span range a | 8pm to 41nm |
8pm to 41nm |
8pm to 40 nm |
8pm to 100 nm |
8pm to 100 nm |
8pm to 85 nm |
8pm to 82 nm |
8pm to 110 nm |
Wavelength resolution (@3dB) a |
5MHz/0.04pm and 100MHz/0.8pm (standard resolution included with OSA-AP5, OSA-AP6 ; Optional for OSA-AP1 with option OSA-AP1-3) 20MHz/0.16pm 140MHz/1.12pm Optical virtual bandwidth resolutions |
|||||||
Absolute wavelength accuracy b |
+/- 2pm Typ. (+/- 3pm Max.) | |||||||
Wavelength repeatability |
< 0.5pm (standard deviation over 20 measures) | |||||||
Dynamic range d | C band c : 86 dB L band /C+L band c : 83 dB |
79dB h | 87dB h | |||||
Close-in dynamic range | >40dB c @ +/- 1.3pm >60dB c @ +/- 8pm; >80dB c @ +/- 30pm |
>40dB h @ +/- 0.1pm; >60dB h @ +/- 0.4pm; >80dB h @ +/- 6pm |
||||||
Spurious free dynamic | 55dB Typical(50dB min) (1) c | 55dB Typical(50dB min) (1) h | ||||||
Measurement level range d | C band c : -76 dBm to +10 dBm L band/C+L band c : -76dBm to +10 dBm |
-73 to +10dBm h | -69dBm to +10dBm h |
-73 to +10dBm h | ||||
Absolute level accuracy aef | +/- 0.3dB (2) (monochromatic input signal) | |||||||
Level repeatabilityf | < +/- 0.1dB (monochromatic input signal ; standard deviation over 20 measures) | |||||||
Sweep time | Max. 35nm/s (filter resolution 100MHz) | |||||||
Optical input | FC/PC for SM fiber (other connectors under request) | |||||||
Dimensions | OSA-AP1 : W x H x D : 488 x 242 x 380.1 mm / 15.27 x 9.57 x 14.96 inch ; OSA-AP5, OSA-AP6 : W x H x D : 450 x 250 x 500 mm / 17.72 x 9.84 x 19.69 inch |
|||||||
Weight | OSA-AP1 : Around 18 kg / 39.68 lbs (depending on options) OSA-AP5, OSA-AP6 : Around 13 kg / 28.66 lbs (depending on options) |
a) Typical
b) After wavelength calibration
c) Resolution 20MHz
d) 4 dB dynamic loss in cas e of p o larimeter
e) At 1550 or 1310 nm and 0dBm
f) All resolutions except 5MHz
g) Resolution 140MHz
h) Resolution 5MHz
i) If modulation frequency = initial repetition rate
1) Inside spurious free dynamic
2) Relative to total signal power
Otherwise: possible power offset
< 10-6 x Total signal power (mW)
OCSA-APx | |
All specifications except modulation analysis related |
Identical as OSA-APx |
Spectrum domain measurement | Intensity, Phase |
Time domain measurement | Intensity, Phase, Chirp, Constellation, Intensity or phase eye diagrams |
Clock input frequency | Clock frequency = repetition rate |
Optical bandwidth | 3THz |
Polarisation | 2 Modulation Analyser, 1 for each polarisation channel |
Clock power | > -17dBm at repetition rate |
Repetition rate (direct measurement) | From 70 MHz to 900MHz |
Repetition rate after modulation i (= Initial repetition rate / pattern length) |
From 70MHz to NO UPPER LIMITATION Including 10, 40, 100, 400GHz, 1THz etc. For example At 100 Gbaud : use any pattern length between 100 and 1428 (PRBS 27-1, 28-1, 29-1, 210-1 included) |
Measured modulation format | ALL |
Optical spectral components measurement sensibility |
-70dBm |
Maximum temporal resolution | 325fs |
Measurement time | 6nm/s (750GHz/s) |
Photo | Product | Price | |
---|---|---|---|
![]() | Apex OSA-APX High Resolution Optical Spectrum Analyser | > |